2017-2018 SunLED Catalog - page 48

TECHNICAL
46
APPLICATION NOTES
The technical notes in this catalog are subject to change without notice.
6. Mounting direction of SMD components should be placed perpendicular to the direction of PCB travel. This will ensure the solder wets
on each lead simultaneously during reflow and prevent shifting of LEDs. Refer to below diagram (Fig.11) for examples of recommended
mounting direction.
8. High temperatures may reduce component’s performance and reliability. Please refer to individual product datasheets for specific
details on operable temperature range and effects of temperature on the LED.
7. High-power LED devices require optimization of heat dissipation. Increasing the size of metal mounting surface and proper application
of thermal conductive paste will help improve heat dissipation. Refer to below diagram (Fig.12) and product datasheets for specific
design recommendations.
Fig. 11
Fig. 12
3. Prevent exposure of LEDs to environments containing high moisture or corrosive gases.
4. Excess operating temperature and/or forward current should be avoided as it may lead to accelerated degradation or failure of the
LED. Always refer to the most updated datasheet for driving conditions.
5. When LEDs are mounted in a parallel configuration, there should be individual current-limiting resistors in series with each LED.
Refer to below diagram (Fig.10) for an example of a recommended set up.
APPLICATION NOTES
1...,38,39,40,41,42,43,44,45,46,47 49,50,51,52